Lynx Smart BMS (NG) v1.14 firmware update

Last month, we released firmware update v1.14 for Lynx Smart BMS (NG), which includes a number of important fixes and improvements, including those specific to the NG (New Generation) series.

More accurate state of charge (SoC) indicators

Improved synchronization between battery monitor and charge control — jumping to 100% SoC now works more stably.

Updated voltage values

Standard charging voltages: 13.9V / 27.8V / 41.7V / 55.6V
(old devices with 14.0V voltage are updated automatically for correct SoC calculation).

Float voltage: 13.5V / 27.0V / 40.5V / 54.0V — now complies with official instructions.

Fixed alarm relay error, which did not trigger when overheating.

Smoother transition to support mode

Especially noticeable when working with Multi or Quattro — system gets more time to stabilize.

NG Series Improvements

Fixed the re-absorption charge timer — now once every 30 days by default.

Added cell ID display for minimum and maximum voltages and temperatures — now visible in VRM (requires latest GX device beta).

Data loop test

  • If you connect the battery BMS ports with a loop cable, the system will close the contactor, but the charge/discharge will be disabled — to check the interface's performance.
  • If the interface is faulty, the contactor will not close.
  • The test starts automatically.

🔄 How to update the firmware?

Updating is possible via GX-devices or the VictronConnect. Contact certified specialists LLC “Total-Energo” for software update services.

Thanks

Thanks to all users and partners who sent bug reports, tested new versions and helped make this update better. Total-Energo LLC recommends always using the latest software for stable and safe operation of Victron Energy-based systems. If you need help with the update — contact our technical support.