Victron Energy VM-3P75CT (part number REL200300100) is a three-phase energy meter supplied with three 75 A split-core current transformers, designed for high-precision measurement of AC consumption or generation. Developed for the Victron Energy ecosystem, the meter connects to Cerbo GX, Ekrano GX, or Venus GX devices via Ethernet or VE.Can ports. It is used in Energy Storage Systems (ESS) to monitor a site's total consumption, track solar power generation, or measure power on specific circuits.
Key advantages of the VM-3P75CT energy meter
- 75 A current transformers included — 3 split-core sensors (Snap-on CTs) install without disconnecting power cables
- Measurement in three-phase, split-phase, and single-phase networks up to 75 A per phase
- Dual data interfaces: Ethernet (RJ45) and VE.Can (2x RJ45, terminators included), with Modbus UDP support
- Ultra-fast data update rate (100 ms) — Instantaneous inverter response in ESS and Zero Feed-in systems
- Real-time energy flow visualization via the Victron VRM portal
- Simple Plug & Play connection with automatic detection by GX devices
- Flexible energy calculation method settings (vector, arithmetic, or absolute)
Technical Specifications
- Part number: REL200300100
- Network type: 3-phase / 4-wire (L1, L2, L3, N); supports single-phase configurations
- Voltage range: 85–265 V AC (phase L-N) / 150–460 V AC (line L-L), 50/60 Hz
- Maximum current: up to 75 A per phase
- Current transformers: 3 split-core sensors (10 mm inner diameter, 640 mm cable length) — included in the package
- Communication interfaces:
- 1x Ethernet port (RJ45, Modbus UDP)
- 2x VE.Can ports (RJ45, VE.Can terminators included)
- Data update rate: 100 ms
- Device power supply: self-powered via L1-N phase (consumption 1.45 W / 3.1 VA)
- Mounting: DIN-rail (standard modular housing, IP20)
- Dimensions and weight: 90 x 71 x 59 mm, 370 g (including packaging)
- Measured parameters:
- Active power (W) per phase and total
- Current (A) per phase and neutral wire
- Phase voltage (L-N) and line voltage (L-L)
- Grid frequency (Hz)
- Power factor (IEEE standard)
- Reactive and apparent power (var, VA)
- Phase sequence monitoring and phase error warning
- Total consumed and generated energy (kWh)
Use cases
- Grid connection point measurement (Grid Meter) for residential and commercial ESS systems
- Dynamic grid export limitation
- (Zero Feed-in) or Net Billing operation
- Metering of solar generation from PV inverters
- Monitoring of output power from three-phase AC generators (AC Genset)
- Monitoring of specific dedicated loads or sub-networks (AC Load)
- Full control and energy consumption history review via the free VRM Portal cloud service
Communication and monitoring interfaces
- Ethernet (RJ45) – direct connection to the local network; data transmission via Modbus UDP protocol
- VE.Can (RJ45) – direct communication via industrial CAN-bus with Cerbo GX and Ekrano GX devices
- VictronConnect – quick configuration of the meter role (Grid, PV Inverter, Genset, AC Load) and network settings via smartphone or PC
- VRM Portal – visualization of power balance graphs, analytics, and remote access from anywhere in the world
Service support in Ukraine
Total-Energo LLC is a certified Victron Energy partner in Ukraine and provides comprehensive support:
- System design
- Equipment selection and supply
- Installation and commissioning
- VRM connection