|
Quantity
|
Total
|
||
|
|
|||
|
|
|||
Phoenix Inverter 24/1600 VE.Direct Schuko (24V, 1600 VA) – is a reliable pure sine wave inverter from Victron Energy, operating at 24V and designed for off-grid energy systems, vehicles, boats, and backup power. With an output power of 1600 VA (1450 W at 25°C), it provides a stable 230V voltage (with a +/-3% deviation), which is essential for powering sensitive electrical appliances.
Thanks to the VE.Direct port, the inverter easily integrates with computers, smartphones, and tablets (Apple and Android) for monitoring and settings.
Key Advantages of the Phoenix Inverter 24/1600 VE.Direct Schuko
- Pure sine wave – stable voltage for sensitive electronic devices.
- Compact housing – dimensions of 117 x 231 x 365 mm allow for convenient installation in any system.
- VE.Direct communication – monitoring and configuration via specialized interfaces.
- High peak power (up to 2100 W) – seamless start-up of devices with high inrush currents, such as LED lamp converters, halogen lamps, or power tools.
- Low power consumption – 14 W in standard mode (Zero-load power), 2 W in ECO Mode.
- ECO Mode – automatic switching to standby mode when the load drops below a preset value (minimum 15 W) to save energy.
- Programmable parameters – adjustment of low battery cut-off, restart levels, frequency (50/60 Hz), and output voltage (210-230 V).
- Temperature range from -40°C to +65°C – high resistance to extreme conditions with a fan-assisted cooling system.
- Reliable protection – protection against output short circuit, overload, excessively high or low battery voltage, and overheating.
Technological Features
- VE.Direct port – allows connecting the inverter to a computer via a VE.Direct-USB cable or to a smartphone via a VE.Direct Bluetooth Smart dongle.
- Remote on/off – via an external two-pole switch or by connecting the battery positive to the left-hand contact of the connector.
- Energy saving function (ECO Mode) – the inverter goes into standby mode and periodically turns on for a short time (every 2.5 seconds by default) to check the load.
- High inrush current protection – stable operation with loads that have a high starting current.
- Dynamic cut-off – the low voltage disconnect level depends on the current load on the system.
- LED diagnostics – visual indication of the device status.
Inverter Usage Scenarios
- Off-grid energy systems – use in solar systems to convert battery energy into alternating current.
- RVs, campers, caravans – powering lighting, laptops, TVs, and chargers.
- Yachts and boats – stable operation of navigation equipment, chargers, and electronics.
- Mobile laboratories, service vehicles – providing power for portable instruments.
- Backup power – autonomous power supply for critical devices in the event of a power outage.
Features ECE R10-4 (EMC) Electromagnetic Compatibility Standard
ECE R10-4 – is an electromagnetic compatibility standard (Automotive Directive) applied to electronic equipment used in vehicles. It regulates the requirements for electromagnetic interference emissions and immunity to external electromagnetic influences.
What does the ECE R10-4 certificate mean for Victron Energy inverters?
Low level of electromagnetic emission
- The inverters do not create radio frequency interference that could affect radio communications, GPS, mobile networks, or other electronic systems of the car, yacht, or industrial machinery.
High immunity to electromagnetic interference
- The inverters operate stably even in harsh environments where sudden voltage changes or strong electromagnetic fields are possible (e.g., in trucks, buses, heavy machinery).
Safe integration into transport systems
- Complies with the requirements of the United Nations Economic Commission for Europe (ECE), allowing the use of inverters in cars, campers, marine vessels, and other vehicles without the risk of negative impact on the electronic systems of the head unit or car safety systems like ABS.
Guarantee of quality and compliance with international standards
- ECE R10-4 compliance confirms that Victron Energy products have passed rigorous testing and meet international safety requirements for use in transport.
What does this offer users of Inverter Smart / Phoenix inverters?
- Legal use in vehicles without the need for additional certification.
- Compatibility with other electronic systems – the inverter does not interfere with the radio, navigation, autopilot, GPS, and other electrical appliances.
- Stable operation in harsh conditions – marine vessels, caravans, commercial vehicles, heavy machinery.
- Protection from electromagnetic waves – the inverter does not fail during sharp voltage fluctuations.
Series Model Comparison
|
Device |
Voltage |
Power |
Peak Power |
Communication |
Size |
|
12/220V |
250VA/200W |
400W |
VE.Direct |
86x165x260mm |
|
|
12/220V |
375VA/300W |
700W |
VE.Direct |
86x165x260mm |
|
|
12/220V |
500VA/400W |
900W |
VE.Direct |
86x172x275mm |
|
|
12/220V |
800VA/650W |
1500W |
VE.Direct |
105x216x305mm |
|
|
12/220V |
1200VA/1000W |
2200W |
VE.Direct |
117x232x362mm |
|
| Inverter 12/1600 VE.Direct Schuko | 12/220V | 1600VA/1450W | 2200W | VE.Direct | 117x232x362mm |
|
24/220V |
250VA/200W |
400W |
VE.Direct |
86x165x260mm |
|
|
24/220V |
375VA/300W |
700W |
VE.Direct |
86x165x260mm |
|
|
24/220V |
500VA/400W |
900W |
VE.Direct |
86x172x275mm |
|
|
24/220V |
800VA/650W |
1500W |
VE.Direct |
105x216x305mm |
|
|
24/220V |
1200VA/1000W |
2200W |
VE.Direct |
117x232x327mm |
|
|
Inverter 24/1600 VE.Direct Schuko |
24/220V |
1600VA/1450W |
2100W |
VE.Direct |
117x231x365mm |
|
48/220V |
250VA/200W |
400W |
VE.Direct |
86x165x260mm |
|
|
48/220V |
375VA/300W |
700W |
VE.Direct |
86x165x260mm |
|
|
48/220V |
500VA/400W |
900W |
VE.Direct |
86x172x275mm |
|
|
48/220V |
800VA/650W |
1500W |
VE.Direct |
105x216x305mm |
|
|
48/220V |
1200VA/1000W |
2200W |
VE.Direct |
117x232x327mm |
Communication Interfaces
- VE.Direct – connection to a PC via USB or to a smartphone via the VE.Direct Bluetooth Smart dongle.
- Remote control – support for connecting an external two-pole switch.
- Connection to the monitoring system – using the VE.Direct port, you can monitor the disconnect, restart, and low battery voltage alarm levels, as well as change the output voltage (210-230 V) and AC frequency (50/60 Hz).