Stark UPS — are online uninterruptible power supply systems with double energy conversion, which are used to protect critical equipment in IT infrastructure, medical institutions, industrial and telecommunications facilities. The brand's line includes single- and three-phase models with wide configuration options, external or internal batteries, as well as built-in interfaces for monitoring. Diagnostics cover all electrical and software components to ensure smooth system operation.
What diagnostics include
Inspection/audit
- External inspection of the housing, ventilation holes, display, terminal connections and status indicators.
- Configuration fixation: system type (single or three-phase), power, connection method, battery packs.
- Checking operating conditions: temperature, humidity, ventilation, compliance of installation with manufacturer's instructions.
- Electrical installation analysis: connection quality, grounding, protective devices.
Electrical tests
- Measurement of input voltage and frequency: checking tolerances, fixing instability or distortions.
- Output voltage control: stability, symmetry (for three-phase), frequency accuracy.
- Analysis of the response to changes in input parameters: dips, voltage peaks, phase loss.
- Checking transition modes: inverter ↔ network ↔ bypass, fixing the switching time and parameters.
Inverter / bypass test
- Evaluation of inverter operation: output voltage, waveform, current, load, temperature.
- Bypass operation test: presence of synchronization, correctness of automatic and manual switching.
- Analysis of emergency modes: overload, short circuit, loss of network, starting from the battery.
Battery (battery system)
- Inspection of battery condition: terminals, housings, cables, ventilation (for external battery units).
- Measurement of the voltage of each cell or section, detection of imbalances and degradation.
- Charger test: Float/Boost modes, parameter stability, current control.
- Autonomous operation test: starting the inverter from Battery, voltage and stability control under load.
Cooling
- Checking fans: speed, noise, temperature control.
- Analysis of the temperature regime of the main components: inverter, bypass, battery.
- Inspection of ventilation ducts, filters and heat exchangers — for contamination or reduced efficiency.
Communications / monitoring
- Checking the display's performance: accessing settings, reading the event log, viewing accidents.
- Testing interfaces: RS-232, USB, SNMP, dry contacts, Modbus (depending on the model).
- Analysis of the connection to the monitoring system or software (for example, ViewPower or similar).
Technical report
- Generation of a technical report indicating all tested nodes and their current status.
- Identification and fixing of worn components, failures or critical deviations.
- Providing recommendations: replacing the battery, cleaning the cooling system, re-parameterization.
When necessary diagnostics
- Every year — within the framework of preventive or scheduled service.
- When the autonomous time decreases, errors, interface failures or alarms appear.
- After installing new batteries or long downtime of equipment.
- Before starting after installation or before overloading the system with new equipment.
Why choose LLC «Total-Energo»
- Experience working with a wide range of UPSs of various brands: Stark, INVT, Kehua, Borri, Riello, etc.
- Professional diagnostics using high-precision instruments and software.
- Formation of a full technical report suitable for internal or external audit.
- Post-diagnostic maintenance: battery replacement, ventilation cleaning, flashing, connecting SNMP cards.
- Service support within warranty, post-warranty and contractual service programs.