Total-Energo LLC” performs specialized diagnostics of modular online INVT RM series Rack-Mounted UPSs (19” rack placement), with a capacity of 20 to 200 kVA. RM Series UPSs — are scalable and redundant systems designed for data centers, server rooms, medical centers and infrastructure with high requirements for uninterrupted power supply.
What does professional INVT RM diagnostics include
1. System and configuration audit
- Determination of the number of power modules and configuration (e.g. 4x25 kVA)
- Checking the status of the switch cabinet chassis, cable connection
- Analysis of the N+X redundancy level, active messages and errors
2. System input/output parameters
- Measurement of voltage, frequency, phase balance
- Checking the quality of the output signal: stability, symmetry, harmonics
- Simulation of bypass transfer, checking the system response
3. Testing power modules
- Checking the operation of each module separately: load, inverter, PFC
- Synchronization between modules, load distribution
- Detecting degradation of one of the modules, imbalance
4. Battery system
- Determining the number and configuration of battery packs (48/96/240/384 V DC)
- Measuring voltage, internal resistance, charge balance
- Testing switching, BMS, thermal protection, terminal condition
5. Cooling assessment
- Checking the fans of each module
- Analysis of temperature sensors, air ducts
- Detection of overheating, clogging, cooling failures
6. Communications and monitoring
- Checking SNMP, Modbus, USB, monitoring interfaces
- Reading the event log: errors, shutdowns, automatic redundancy
- Alarm test: local and remote
7. Technical report and recommendations
- Conclusions for each module, the system as a whole, the battery
- Life expectancy and recommendations for modernization
- Recommendations for optimizing balancing, firmware updates, service
When diagnostics are needed
- Annually or when changing the configuration (expansion, replacement of modules)
- When unstable operation, reduced reserve, overheating are detected
- After an emergency shutdown, prolonged autonomous mode
- Regular maintenance for data centers, financial institutions, medical institutions
Why choose LLC “Total-Energo”
- Experience with modular systems INVT RM, SOCOMEC, Huawei, Eaton
- Own engineers with experience in diagnosing modules up to 50 kVA
- Official reporting for SLA, modernization and replacement of batteries, fans
- Support throughout Ukraine, fast response, 24/7 technical support