Total-Energo LLC performs professional diagnostics of three-phase uninterruptible power supplies (UPS) of the General Electric Lan Pro LP31 series. These are industrial uninterruptible power supply systems with a 3/1 output (three-phase input connection, single-phase output), which are used for critical loads in industry, data centers, medical institutions and communication facilities.
What does a full GE LP31 UPS diagnostics include
1. Visual inspection and connection check
- Inspection of the housing, terminal condition, panel connection
- Analysis of the indication on the control panel
- Check for active alarms, faults or warnings
2. Testing input/output parameters
- Measurement of input voltage across all phases
- Checking phase balance and frequency stability
- Measurement of output voltage at different loads
3. Checking the inverter part
- Checking double conversion mode (online)
- Testing the transition to the battery and back
- Checking the bypass mode, automatic and manual switching functions
4. Battery circuit check
- Measurement of the voltage of the battery group and individual cells
- Checking battery wear (resistance, residual capacity — if available)
- Analysis of temperature conditions and connection status
5. Cooling and safety system
- Checking the operation of fans and temperature sensors
- Detection of overheating, dust contamination
- Monitoring emergency stops due to overheating
6. Event and alarm log analysis
- Reading logs via interface (RS232 / SNMP / ViewPower)
- Estimating the number of cycles, failures, shutdowns, starts from the battery
- Checking the operation of alarm interfaces, testing relay outputs
7. Report, conclusions and recommendations
- Formation of a technical conclusion
- Estimation of the remaining resource of the system and battery
- Proposals for component replacement, service or modernization
When diagnostics are necessary
- After 3-5 years of operation or long downtime
- In case of detection of alarms, failures during switching or unstable operation
- Before replacing the battery or if overheating, noise, reduction of reserve is suspected
- For scheduled maintenance at critical infrastructure facilities
Why choose LLC “Total-Energo”
- Experience working with GE LP31, LP33, SG, TLE, GT6000/10000
- Full service support: diagnostics, installation, battery replacement, maintenance
- Own warehouse of spare parts and batteries, delivery throughout Ukraine
- Provision of an official technical report and warranty for services